1,011 research outputs found

    Fabrication and characterization of novel multilayered structures by stereocomplexion of poly(D-lactic acid)/poly(L-lactic acid) and self-assembly of polyelectrolytes

    Get PDF
    The enantiomers poly(D-lactic acid) (PDLA) and poly(L-lactic acid) (PLLA) were alternately adsorbed directly on calcium carbonate (CaCO3) templates and on poly(styrene sulfonate) (PSS) and poly(allylamine hydrochloride) (PAH) multilayer precursors in order to fabricate a novel layer-by-layer (LBL) assembly. A single layer of poly(L-lysine) (PLL) was used as a linker between the (PDLA/PLLA)n stereocomplex and the cores with and without the polymeric (PSS/PAH)n/PLL multilayer precursor (PEM). Nuclear magnetic resonance (NMR) and gel permeation chromatography (GPC) were used to characterize the chemical composition and molecular weight of poly(lactic acid) polymers. Both multilayer structures, with and without polymeric precursor, were firstly fabricated and characterized on planar supports. A quartz crystal microbalance (QCM), attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) and ellipsometry were used to evaluate the thickness and mass of the multilayers. Then, hollow, spherical microcapsules were obtained by the removal of the CaCO3 sacrificial template. The chemical composition of the obtained microcapsules was confirmed by differential scanning calorimetry (DSC) and wide X-ray diffraction (WXRD) analyses. The microcapsule morphology was evaluated by scanning electron microscopy (SEM) and transmission electron microscopy (TEM) measurements. The experimental results confirm the successful fabrication of this innovative system, and its full biocompatibility makes it worthy of further characterization as a promising drug carrier for sustained release

    CMS Drift Tube Chambers Read-Out Electronics

    Get PDF
    With CMS installation nearing completion, the three levels of the final read-out system of the Drift Tube (DT) chambers are presented. First, are the Read Out Boards (ROB), responsible for time digitization of the signals generated by a charged particle track. Second, the Read Out Server (ROS) boards receive data from 25 ROB channels through a 240-Mbps copper link and perform data merging for further transmission through a 800 Mbps optical link. Finally, the Detector Dependent Units (DDU) merge data from 12 ROS to build an event fragment and send it to the global CMS DAQ through an S-LINK64 output at 320 MBps. DDUs also receive synchronization commands from the TTC system (Timing, Trigger, and Control), perform error detection on data, and send a fast feedback to the TTS (Trigger Throttling System). Functionality of these electronics has been validated in the laboratory and in several test-beams, including an exercise integrated with a fraction of the whole CMS detector and electronics that demonstrated proper operation and integration within the final CMS framework

    Harmonization and standardization of data for a pan-European cohort on SARS- CoV-2 pandemic

    Get PDF
    The European project ORCHESTRA intends to create a new pan-European cohort to rapidly advance the knowledge of the effects and treatment of COVID-19. Establishing processes that facilitate the merging of heterogeneous clusters of retrospective data was an essential challenge. In addition, data from new ORCHESTRA prospective studies have to be compatible with earlier collected information to be efficiently combined. In this article, we describe how we utilized and contributed to existing standard terminologies to create consistent semantic representation of over 2500 COVID-19-related variables taken from three ORCHESTRA studies. The goal is to enable the semantic interoperability of data within the existing project studies and to create a common basis of standardized elements available for the design of new COVID-19 studies. We also identified 743 variables that were commonly used in two of the three prospective ORCHESTRA studies and can therefore be directly combined for analysis purposes. Additionally, we actively contributed to global interoperability by submitting new concept requests to the terminology Standards Development Organizations

    On the electromagnetic energy resolution of Cherenkov-fiber calorimeters

    Get PDF
    Electromagnetic calorimeters which sample the Cherenkov radiation of shower particles in optical fibers operate in a markedly different manner from calorimeters which rely on the dE/dx of shower particles. The well-understood physics of electromagnetic shower development is applied to the case of Cherenkov-fiber calorimetry (also known as quartz fiber calorimetry) and the results of systematically performed studies are considered in detail to derive an understanding of the critical parameters involved in energy measurement using such calorimeters. A quantitative parameterization of Cherenkov-fiber calorimetry electromagnetic energy resolution is proposed and compared with existing experimental results

    Performance of the readout system of the ALICE Zero Degree Calorimeters in LHC Run 3

    Get PDF
    The ALICE Zero Degree Calorimeters (ZDC) provide information about event geometry in heavy-ion collisions through the detection of spectator nucleons and allow to estimate the delivered luminosity. They are also very useful in p–A collisions, allowing an unbiased estimation of collision centrality. The Run 3 operating conditions will involve a tenfold increase in instantaneous luminosity in heavy-ion collisions, with event rates that, taking into account the different processes, could reach 5 MHz in the ZDCs. The challenges posed by this demanding environment lead to a redesign of the readout system and to the transition to a continuous acquisition. The new system is based on 12 bit, 1 Gsps FMC digitizers that will continuously sample the 26 ZDC channels. Triggering, pedestal estimation and luminosity measurements will be performed on FPGA directly connected to the front-end. The new readout system and the performances foreseen in Run 3 are presented

    Primary breast lymphomas

    Get PDF
    The diagnosis, prognostic factors, and optimal management of primary breast lymphomas (PBL) is difficult. Seven patients recorded at the Geneva Cancer Registry between 1973–1998 were reviewed. Five patient had diffuse large B-cell lymphoma, one a follicular lymphoma and one a MALT-lymphoma. All patients had clinical and radiological findings consistent with breast cancer and underwent mastectomy, which is not indicated in PBL. Diagnosis should be established prior to operative interventions, as fine needle aspiration missed the diagnosis for one patient and intra-operative frozen sections for 3 patients in our study. Five-year and 10-year overall survivals were 57% and 15%, respectively. Of the 3 patients who died from PBL, 2 had tumors that were Bcl-2 positive but Bcl-6 negative. All 3 surviving patients have positive Bcl-2 and Bcl-6 immunostaining, which could be important prognostic factors if confirmed by a larger study
    • 

    corecore